- Excavator:
- 311D-345D
- 365C-385C
ReferenceTesting and Adjusting for each model.
Service allowance pressure settings are available for setting the main relief valve and the line relief valves for certain Excavators. Refer to the following tables for a listing of the factory pressures settings and the field allowance setting. The factory standard for pressure setting is 35000 ± 500 kPa (5075 ± 73 psi) for standard and 38000 ± 500 kPa (5500 ± 73 psi) for heavy lift. This standard is a factory set pressure that is used during machine assembly. Pressures that are measured in the field might be out of this range due to the accuracy of the pressure gage, tolerance in the measurement or interpretation of the gage reading. A new 198-4240 Digital Pressure Indicator Gp provides a more accurate setting of the main valve and the line relief valves.
Refer to the field inspection allowance in the following tables to determine if the measured pressures are normal. refer to 'Test and Adjusting- Relief Valve' of each Models for measurement or readjustment of the relief valve. Refer to Test and Adjusting, "Relief Valve" of each model for measurement or readjustment of the relief valve.
Models     |     | Factory Inspection     | Field Inspection     | ||
---|---|---|---|---|---|
Factory set | Service allowance     | ||||
311D RR 311D LRR 312D 313D CR 313D SR 314D CR     |
STD kPa-psi     |
30500 ± 500 kPa (4425 ± 73 psi)     |
30000 kPa (4350 psi) to 31000 kPa (4500 psi)     |
30500 + 500 - 2000 kPa (4425 + 73 - 290 psi)     |
28500 kPa (4133 psi) to 31000 kPa (4496 psi)     |
Models     |     | Factory Inspection     | Field Inspection     | ||
---|---|---|---|---|---|
Factory set | Service allowance     | ||||
315D 315D DL 319D L 319D LN     |
STD kPa-psi     |
35000 ± 500 kPa (5075 ± 73 psi)     |
34500 kPa (5000 psi) to 35500 kPa (5150 psi)     |
35000 + 500 - 2000 kPa (5100 + 73 - 290 psi)     |
33000 kPa (4800 psi) to 35500 kPa (5150 psi)     |
Models     |     | Factory Inspection     | Field Inspection     | ||
---|---|---|---|---|---|
Factory set | Service allowance     | ||||
320D 320D DL 320D RR 320D LN 320D FM 320D MH 321D CR 323D 323D DL 324D 324D DL 324D LN 325D 325D DL 325D LN 328D LCR 329D 329D DL 330D 330D DL 336D 336D DL     |
STD kPa-psi     |
35000 ± 500 kPa (5075 ± 73 psi)     |
34500 kPa (5000 psi) to 35500 kPa (5150 psi)     |
35000 + 500 - 2000 kPa (5100 + 73 - 290 psi)     |
33000 kPa (4800 psi) to 35500 kPa (5150 psi)     |
Heavy Lift | 36000 ± 500 kPa (5221 ± 73 psi)     |
35500 kPa (5150 psi) to 36500 kPa (5300 psi)     |
36000 + 500 - 2000 kPa (5200 +73 - 290 psi) ()     |
34000 kPa (4930 psi) to 36500 kPa (5300 psi)     |
|
Models     |     | Factory Inspection     | Field Inspection     | ||
---|---|---|---|---|---|
Factory set | Service allowance     | ||||
345D 345D DL 345D LC 345D VG     |
STD kPa-psi     |
35000 ± 500 kPa (5075 ± 73 psi)     |
34500 kPa (5000 psi) to 35500 kPa (5150 psi)     |
35000 + 500 - 2000 kPa (5100 + 73 - 290 psi)     |
33000 kPa (4800 psi) to 35500 kPa (5150 psi)     |
Heavy Lift | 38000 ± 500 kPa (5500 ± 73 psi)     |
37500 kPa (5450 psi) to 38500 kPa (5584 psi)     |
38000 + 500 - 2000 kPa (5500 ± 73 - 290 psi)     |
36000 kPa (5225 psi) to 38500 kPa (5600 psi)     |
|
Models     |     | Factory Inspection     | Field Inspection     | ||
---|---|---|---|---|---|
Factory set | Service allowance     | ||||
365C L 385C 385C L 385C FL     |
STD kPa-psi     |
32000 ± 500 kPa (4650 ± 75 psi)     |
31500 kPa (4575 psi) to 32500 kPa (4725 psi)     |
32000 + 500 - 2000 kPa (4650 + 73 - 290 psi)     |
30000 kPa (4350 psi) to 32500 kPa (4700 psi)     |
Heavy Lift kPa-lbs |
35000 ± 500 kPa (5075 ± 75 psi)     |
34500 kPa (5000 psi) to 35500 kPa (5150 psi)     |
35000 ± 500 - 2000 kPa (5075 ± 73 - 290 psi)     |
33000 kPa (4800 psi) to 35500 kPa (5150 psi)     |
|