315C Excavator Machine Systems Accumulator (Hydraulic Pilot) - Remove and Install Caterpillar


Accumulator (Hydraulic Pilot) - Remove and Install
`
315C Excavator Machine Systems [RENR5525]
HYDRAULIC SYSTEM
ACCUMULATOR GP
315C Excavator Machine Systems Accumulator (Hydraulic Pilot) - Remove and Install
1.1. Removal Procedure
2.1. Installation Procedure

Removal Procedure

Start By:

  1. Release hydraulic system pressure. Refer to Disassembly and Assembly, "Hydraulic System Pressure - Release".


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "AVSpare Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on AVSpare products.

Dispose of all fluids according to local regulations and mandates.


------ WARNING! ------

At operating temperature, the hydraulic oil is hot and under pressure. Hot oils can cause burns.

To prevent possible personal injury, release the pressure in the implement hydraulic circuit (boom, stick, bucket, and swing), travel circuits, and the hydraulic oil tank at the filler cap before any hydraulic lines or components are disconnected or removed.

Remove the filler cap only when the engine is stopped and the filler cap is cool enough to touch.

----------------------



    Illustration 1g01019667

  1. Turn hex nut (2) that is located at the bottom of accumulator (1) in order to remove accumulator (1). Remove the O-ring seal from accumulator (1) .

Installation Procedure


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "AVSpare Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on AVSpare products.

Dispose of all fluids according to local regulations and mandates.


    Note: Check the condition of the O-ring seal prior to the installation of the accumulator. If the O-ring seal is worn or damaged, use a new part for replacement.




    Illustration 2g01019667

  1. Install the O-ring seal on accumulator (1). Install accumulator (1) by turning hex nut (2) that is located at the bottom of accumulator (1) .

  1. Check the oil level in the hydraulic oil tank. Fill the hydraulic oil tank to the correct level. Refer to Operation and Maintenance Manual, "Lubricant Viscosities and Refill Capacities" for the correct oil and the correct level for the hydraulic oil system.

Information System:

5130B Excavator Ether Starting Aid Cylinder - Replace
345B Series II Excavator Specifications
345B Series II Excavator Specifications
2002/07/01 New Backup Rings Are Available for Sealing Hydraulic Cylinders with Pitted Grooves {4303, 5102, 5104, 5106, 5456, 7562}
Operating Instructions for the 320C with Material Handler{7000}
311C and 314C Excavators Electric and Electronic Governor Actuator - Check
5130B Excavator Engine Oil and Filter - Change
320C and 322C Forest Machines Hydraulic System Main Hydraulic System
320C and 322C Forest Machines Hydraulic System Main Hydraulic System
320C and 322C Forest Machines Hydraulic System Pilot Hydraulic System
5130B Excavator Engine Oil Level - Check
M316C, M318C and M322C Excavators and M318C and M322C Material Handlers Radiator Core - Clean
345B Series II Excavator Specifications
315C Excavator Machine Systems Gear Pump (Pilot) - Remove and Install
345B Series II Excavator Specifications
345B Series II Excavator Specifications
315C Excavator Machine Systems Hydraulic Tank and Filter - Remove
315C Excavator Machine Systems Main Hydraulic Pump - Install
315C Excavator Machine Systems Main Control Valve - Remove
320C and 322C Forest Machines Hydraulic System Main Control Valve
315C Excavator Machine Systems Auxiliary Pilot Valve (Straight Travel) - Remove
315C Excavator Machine Systems Solenoid Valve (Two-Way Flow and One Pump/Two Pump) - Remove
315C Excavator Machine Systems Main Control Valve - Assemble
315C Excavator Machine Systems Auxiliary Pilot Valve (Straight Travel) - Disassemble