Installation Procedure
Required Tools     | |||
Tool     | Part Number     | Part Description     | Qty     |
(A)     | FT-2674     | Vacuum Cap     | 1     |
Note: Check the O-ring seals, the gaskets, and the seals for wear or for damage and replace the components, if necessary.
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "AVSpare Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on AVSpare products. Dispose of all fluids according to local regulations and mandates. |
- Remove the cap from the hydraulic tank. Attach Tooling (A) to the hydraulic tank.
Note: Hook up the air to Tooling (A) in order to create a vacuum in the hydraulic system. This will minimize the leakage from the hoses.
![]() | |
Illustration 1 | g00797829 |
- Position pilot valve (6) on the mounting bracket. Install wiring clip (5). Install four bolts (4) .
![]() | |
Illustration 2 | g00803199 |
- Connect electrical connector (1) to the solenoid valve. Install new tie (2) .
![]() | |
Illustration 3 | g00803069 |
- Remove plugs and caps from the hose assemblies. Install six hose assemblies (3) .
Note: A small amount of oil will drain from all of the hoses when the hoses are disconnected. Make sure that you contain the hydraulic oil.
- Remove Tool (A) and install the cap to the hydraulic tank.
- Close the access door on the right side of the machine.