Contact with high pressure fuel may cause fluid penetration and burn hazards. High pressure fuel spray may cause a fire hazard. Failure to follow these inspection, maintenance and service instructions may cause personal injury or death. |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Dispose of all fluids according to local regulations and mandates. |
Start By:
- Remove fuel injection lines.
- Remove bolts (2) and fuel manifold (1).
Note: Do not remove the pressure limiter and the rail pressure sensor from fuel manifold (1).
Note: When removing fuel manifold (1) do not hold it by the pressure limiter and the rail pressure sensor.
![]() | |
Illustration 1 | g06008153 |
- Install fuel manifold (1) in the reverse order of removal.
- Tighten bolts (2) to a torque of
24 N·m to 27 N·m (212 lb in to 239 lb in) .
- Tighten bolts (2) to a torque of