416E, 420E and 430E Backhoe Loaders MID 039 - CID 2237 - FMI 05 Caterpillar


MID 039 - CID 2237 - FMI 05
`

Conditions Which Generate This Code:




Illustration 1g01531376

Schematic of the "E-Stick Cylinder Retract" solenoid

This diagnostic code is associated with the retract solenoid valve. The FMI 05 means that the ECM has determined that an open in the circuit exists.

The possible causes of this diagnostic code are listed below:

  • The energize circuit of the solenoid is open.

  • The return circuit of the solenoid is open.

  • The solenoid has failed.

  • The ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2237 FMI 05 is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

System Response:

  • The system will not initialize after power is cycled.

  • The hydraulic functions for the extend, retract, reverse and forward are lost after power is cycled.

  • There will be no effect to the systems after powerup until the next reset of the "Valve" ECM.

Test Step 1. CHECK THE SOLENOID.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  1. Disconnect the solenoid with the active diagnostic code from the machine harness.

  1. At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire T971-OR) to contact 2 (wire E540-PK).

  1. Observe the status of the CID 2237 FMI 05 diagnostic code.

Expected Result:

The CID 2237 FMI 05 diagnostic code remains active. The FMI has not changed and the 05 is still active.

Results:

  • YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.

  • NO - The diagnostic is no longer active. The solenoid has failed.

    Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

Test Step 2. CHECK THE HARNESS FOR AN OPEN.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness connector(s) from the "estick aux valve" stack.

  1. The jumper wire that was installed in the previous Test Step remains in place.

  1. At the machine harness connector, measure the resistance from signal contact 1 (wire T971-OR) to contact 2 (wire E540-PK).

Expected Result:

The resistance is less than 5 ohms.

Results:

  • OK - The resistance is less than 5 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - The resistance is greater than 5 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.

    Repair: The open is in the wire that energizes the circuit (wire T971-OR) or in the wire for the ground connection (wire E540-PK) of the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the contacts of the harness connectors and clean the harness connectors.

  1. Reconnect all harness connectors.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the CID 2237 FMI 05 diagnostic code.

Expected Result:

The CID 2237 FMI 05 diagnostic code is active.

Results:

  • YES - The CID 2237 FMI 05 diagnostic code is active. The diagnostic code has not been corrected. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Replace the machine ECM if the cause of the diagnostic code is not found. See Troubleshooting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 2237 FMI 05 diagnostic code is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Information System:

416E, 420E and 430E Backhoe Loaders MID 039 - CID 2237 - FMI 03
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2237 - FMI 02
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2236 - FMI 06
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2236 - FMI 05
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2236 - FMI 03
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2236 - FMI 02
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2108 - FMI 08
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2108 - FMI 04
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2108 - FMI 03
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2108 - FMI 02
416E, 420E and 430E Backhoe Loaders MID 039 - CID 1960 - FMI 09
416E, 420E and 430E Backhoe Loaders MID 039 - CID 1959 - FMI 08
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2237 - FMI 06
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2242 - FMI 02
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2242 - FMI 03
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2242 - FMI 05
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2242 - FMI 06
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2243 - FMI 02
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2243 - FMI 03
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2243 - FMI 05
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2243 - FMI 06
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2244 - FMI 02
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2244 - FMI 03
416E, 420E and 430E Backhoe Loaders MID 039 - CID 2244 - FMI 05