"Pump Control (Negative Flow) - Test" | ||
---|---|---|
Measured Items | Measuring Points | |
Machine Settings | Engine Speed | Engine speed dial "10"
AEC switch OFF |
Pump Pressure | No Load Standby Pressure | |
Pump Flow Limit Pressure | |
|
Drive Pump Flow Measured L/min (US gpm) | ||
Engine Speed (rpm) | ||
Oil Temperature °C (°F) | ||
Idler Pump Flow Measured L/min (US gpm) | ||
Engine Speed (rpm) | ||
Oil Temperature °C (°F) | ||
Specification for negative flow rate L/min (US gpm) | |
(1) | Negative Flow Control Adjustment |
![]() | |
Illustration 1 | g06016434 |
Pressure/Flow characteristic curve |
Note: Specifications for flow rates are based on an engine speed of 1500 rpm. To get more accurate test results, measured flow should be corrected with the following calculation.
Corrected flow | = | Measured flow x 1500 rpm |
Measured rpm |
Flow measurements must be done only during pressure rise.
This test measures individual pump flow at the pump while a fixed negative flow control pressure is sent to the main pump regulator. Each pump is tested individually for an output flow rate at a specified delivery pressure and a specified negative flow control pressure.
The following procedures must be completed before performing the test procedure.
- Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.
- Calibrate the power shift pressure. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)" for the machine.
![]() | |
Illustration 2 | g02571852 |
Tooling (A) 198-4240 Digital Pressure Indicator Gp |
![]() | |
Illustration 3 | g02535237 |
Tooling (C) |
![]() | |
Illustration 4 | g02793286 |
Tooling (D) (Flow meter tool layout) |
![]() | |
Illustration 5 | g03324637 |
Tooling (E) |
Required Tools | ||||
---|---|---|---|---|
Tool | Item | Qty | Part
Number |
Description |
A | 198-4240 | Digital Pressure Indicator Gp | ||
A1 | 1 | 198-4234 | Indicator | |
A2 | 1 | 198-4237 | Pressure Sensor
|
|
A2 | 2 | 198-4239 | Pressure Sensor
|
|
A3 | 3 | 198-4236 | Extension Cable | |
C | 348-5430 | Multi-Tool Gp | ||
C1 | 1 | 285-0908 | Multi-Tool | |
C2 | 1 | 6V-2198 | Cable As | |
C3 | 1 | 9U-5140 | Photo Pickup | |
C4 | 1 | 6V-3137 | Base | |
C5 | 1 | 1U-6605 | Reflective Tape | |
C6 | 1 | 6V-3138 | Extension | |
D | D1 | 1 | 4C-9910 | Portable hydraulic tester (flow meter) |
D2 | 2 | 6K-6307 | O-Ring Seal | |
D3 | 2 | 8C-9026 | Adapter | |
D4 | 8 | 7M-8485 | O-Ring Seal | |
D5 | 4 | 4C-6482 | Fitting | |
D6 | 4 | 4C-6481 | Coupler | |
D7 | 4 | 4C-8767 | Coupling | |
D8 | 4 | 5P-1010 | Sleeve | |
D9 | 2 | 5P-0201 | Hose | |
D10 | 2 | 4I-6140 | Adapter | |
D11 | 1 | 6V-9511 | Plug | |
D12 | 1 | 6V-9853 | Elbow | |
D14 | 4 | 6V-9746 | O-Ring Seal | |
D15 | 1 | 6V-9839 | Swivel Tee | |
E | E1 | 3 | 6V-8397 | O-Ring Seal |
E2 | 1 | 6V-9508 | Plug | |
E3 | 2 | 8T-8902 | Swivel Tee | |
E4 | 2 | 3J-1907 | O-Ring Seal | |
E5 | 2 | 6V-3989 | Fitting | |
E6 | 1 | 6V-9829 | Cap | |
E7 | 2 | 6V-4143 | Coupler | |
E8 | 1 | 177-7860 | Hose | |
F | 1 | 311-1362 | Vacuum Cap |
Reference: Refer to Tool Operating Manual, NEHS1087 for operating instructions for the 348-5430 Multi-Tool Gp.
Note: Use Software License Card, NETG5049 with part number 348-5430 Multi-Tool Gp.
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products. Dispose of all fluids according to local regulations and mandates. |
Note: Perform the test for the drive pump and the test for the idler pump one at a time.
![]() | |
Illustration 6 | g03324515 |
Flow meter tool layout Tooling (D) ( 4) Delivery line for drive pump (5) Delivery line for idler pump (8) Seal (9) Makeup line (10) Seal (11) Elbow |
- Position the machine on level ground.
- Stop the engine.
- Release pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
- Attach 311-1362 Vacuum Cap onto the hydraulic tank. Attach an air supply hose onto the assembly. Apply
276 to 414 kPa (40 to 60 psi) . This procedure will pull a vacuum on the hydraulic system.
- Disconnect delivery line (4) from the drive pump.
- Install seal (8) and plug (D11) to the end of the delivery line.
- Assemble and install seals (D14), elbow (D12), adapter (D10), seal (D4), and fitting (D5) on the drive pump.
Show/hide table
Illustration 8 g03324497 Swing motor
(9) Makeup line
(10) Seal
(11) Elbow - Disconnect makeup line (9) from elbow (11) at the swing motor.
- Assemble and install seals (D14), tee (D15), adapter (D10), seal (D4), and fitting (D5) to elbow (11) at the swing motor.
- Connect seal (10) and makeup line (9) to tee (D15).
- Connect portable hydraulic tester (D) and test hoses between coupling assembly at the drive pump and coupling assembly at the swing motor.
Show/hide table
Illustration 9 g03323137 Pump compartment
Tooling (E)
( 3) Pressure tap (power shift pressure)
(4) Delivery line for drive pump
(5) Delivery line for idler pump
(6) Negative flow control line (drive pump)
(7) Negative flow control line (idler pump)
(12) Connector
(13) Seal - Disconnect negative flow control line (6) from connector (12) and install plug (E2) and seal (13).
- Install Tooling (E) between connector (12) and pressure tap (3).
- Attach a
3447 kPa (500 psi) pressure sensor (A2) to pressure tap (E5) to monitor negative flow control pressure for the drive pump. - Remove 311-1362 Vacuum Cap and install the filler plug for the hydraulic tank.
- Attach a
41,368 kPa (6,000 psi) pressure sensor to pressure tap (1) for delivery pressure of the drive pump. - Install multi-tool group (C) on the engine to monitor engine speed.
![]() | |
Illustration 7 | g02788589 |
Pump compartment (1) Pressure tap (delivery pressure for drive pump) (2) Pressure tap (delivery pressure for idler pump) (3) Pressure tap (power shift pressure) (4) Delivery line for drive pump (5) Delivery line for idler pump (6) Negative flow control line (drive pump) (7) Negative flow control line (idler pump) |
- Disconnect delivery line (5) from the idler pump.
- Install seal (8) and plug (D11) to the end of the delivery line.
- Assemble and install seals (D14), elbow (D12), adapter (D10), seal (D4), and fitting (D5) on the idler pump.
Show/hide table
Illustration 11 g03324497 Swing motor
(9) Makeup line
(10) Seal
(11) Elbow - Disconnect makeup line (9) from elbow (11) at the swing motor.
- Assemble and install seals (D14), tee (D15), adapter (D10), seal (D4), and fitting (D5) to elbow (11) at the swing motor.
- Connect seal (10) and makeup line (9) to tee (D15).
- Connect portable hydraulic tester (D) and test hoses between coupling assembly at the idler pump and coupling assembly at the swing motor.
Show/hide table
Illustration 12 g03324788 Pump compartment
Tooling (E)
( 3) Pressure tap (power shift pressure)
(4) Delivery line for drive pump
(5) Delivery line for idler pump
(6) Negative flow control line (drive pump)
(7) Negative flow control line (idler pump)
(12) Connector
(13) Seal - Disconnect negative flow control line (7) from connector (14) and install plug (E2) and seal (13).
- Install Tooling (E) between connector (14) and pressure tap (3).
- Attach a
3447 kPa (500 psi) pressure sensor (A2) to pressure tap (E5) to monitor negative flow control pressure for the idler pump. - Remove 311-1362 Vacuum Cap and install the filler plug for the hydraulic tank.
- Attach a
41,368 kPa (6,000 psi) pressure sensor to pressure tap (2) for delivery pressure of the idler pump. - Install multi-tool group (C) on the engine to monitor engine speed.
![]() | |
Illustration 10 | g02788589 |
Pump compartment (1) Pressure tap (delivery pressure for drive pump) (2) Pressure tap (delivery pressure for idler pump) (3) Pressure tap (power shift pressure) (4) Delivery line for drive pump (5) Delivery line for idler pump (6) Negative flow control line (drive pump) (7) Negative flow control line (idler pump) |
Note: Perform the test for the drive pump and the test for the idler pump one at a time.
![]() |
To prevent personal injury or equipment damage from failure of the hydraulic test equipment or associated circuit components because of blocked pump flow, make sure that the test equipment valves are fully open before starting the engine. |
![]() |
To prevent personal injury and/or equipment damage from failed lines or components while the hydraulic test equipment is returned to the open flow position, slowly open the hydraulic test equipment valve while monitoring the pump flow. If pump flow does not increase as the valve is opened, shut the engine off and determine what is preventing the pump from upstroking. |
- Start the engine.
- Increase the hydraulic oil temperature to
55° ± 5°C (131° ± 9°F) . - Enter the service mode.
- Input the password "9992".
- Select "Override Parameters".
- Set the engine speed to 1500 rpm.
- Set the "Power Shift Pressure" to
3000 kPa (435 psi) . Confirm the power shift pressure at pressure tap (E5).
Show/hide tableIllustration 13 g02599896 Portable hydraulic tester (flow meter)
(D1) Portable hydraulic tester (flow meter)
(17) Valve - Turn valve (17) on the portable hydraulic tester clockwise. The measuring point is listed in Table 1. Use the pressure sensor at pressure tap (1) to monitor the delivery pressure of the drive pump. Use pressure tap (2) to monitor the delivery pressure of the idler pump.
Note: To perform flow measurements for either one of the pumps, the other pump must not be under load.